Free Shipping and No Hassle Returns
Free Shipping
We offer free shipping on orders over $199.*
No Hassle Returns
Don’t like it? Send it back. It’s that simple.*
Same Day Shipping
Most orders ship same day if placed by 5PM EST (M-F)
*Restrictions Apply. See Details »
Free Shipping on orders over $199 $99
Same day shipping on most orders
Need it before Christmas? Click here for Shipping Calculator
Model#: GRCN6294
Condition:
New

What are the different product conditions?

New
Brand new items;Full manufacturer warranty available
Reconditioned
Manufacturer inspected, repaired and tested items; CPO 60 day money back guarantee
Open Box
New or Recon items with possible minor cosmetic damage; CPO 60 day money back guarantee
Certified
Returned items inspected, repaired and tested by CPO technicians; CPO 60 day money back guarantee

Generac 6294 30 Amp 120/240 Single Phase Pre-Wired Manual Transfer Switch for Portable Generators Up to 8 kW

  • Generac 6294 30 Amp 120/240 Single Phase Pre-Wired Manual Transfer Switch for Portable Generators Up to 8 kW
List:
$399.99
Sale Price:
$299.00
You Save
25%
Free Shipping
(continental U.S.)
+
Tyler Tool Protection Plans are not currently offered to residents of California
Qty:
-
+
In Stock
Ships Today
  • Need it before Christmas? Click Here for shipping deadlines.

    Christmas Shipping Cut Offs

    Enter your zip code for estimated shipping dates

    Order by the dates below to get delivery by Christmas
    Standard Delivery *Enter zip code for order by date
    Express Delivery
    Priority Delivery
    Premium Delivery

    Orders must be placed by 5PM EST.

    Certain items require 2-3 business days to ship and is clearly indicated on the product page. These items cannot be expedited.

    Delivery times on Economy and Freight orders vary, exact delivery date cannot be determined.

Details

Safely and easily deliver power from your portable generator to your home's electrical panel during a power outage. With a Generac manual transfer switch, you no longer need to run extension cords to your appliances, and you can even back up hard-wired appliances like your furnace or water heater.
Features:
  • The safest way to distribute power to your home
  • Eliminates dangerous back feeds and electrical overloads
  • Pre-wired for 6 circuits (expandable to 10) with interchangeable breakers making it easy to reconfigure or expand
  • Hard-wired circuits provide the electricity you need to power your furnace, sump pumps and more
  • Built-in wattage meter tracks power input to ensure proper load balancing
  • Position like a subpanel inside your home or garage
  • Please note: Requires 2-Pole 60 Amp breaker in main load center and power inlet box must be hardwired
Includes:
  • 30 Amp Power Inlet Box
  • 10 ft. Power Cord
  • Wiring Harness and Connectors
  • Conduit and Fittings
  • Installation Manual
Downloads:

Specifications

Length: 9.25 in.
Width: 11.25 in.
Depth: 3.4 in.
Weight: 19 lbs.

Recommendations

Reviews

4.5 / 5.0
2 Reviews
5 Stars
4 Stars
3 Stars
2 Stars
1 Star
1
1
0
0
0
Would you recommend?
Yes (2)
Recommendations
Yes, I would recommend this to a friend
"I would buy this product again.
For power outages, with Generac 8kw/10kw generator.
April 8, 2013
Recommendations
Yes, I would recommend this to a friend
Nice, but wiring space is limited...
I wanted to use a larger wire gauge from the inlet box to the transfer switch, in order to minimize voltage drops (plus, I had the 8-4 cable) but found that this made things tight. The inlet box and switch panel are clearly designed for #10 wire. The inlet box and enclosure for the breakers could be a little larger. Plus, a 10 foot cable for the generator is a little short. It really should be 15-20 feet, to allow the generator to be placed farther from the structure. Overall, a good complete basic kit, though.
February 12, 2013

Questions & Answers

Start typing your question and we'll check if it was already asked and answered. Learn More
Browse 1 question Browse 1 question and 1 answer
I have you GP6500E generator and the manual specifically says to use a 3-pole transfer switch because the neutral wire is bonded to ground on this generator and a 2-Pole swtch will not work. Is this a 3-Pole switch?
Art on Oct 6, 2015
BEST ANSWER: No, this transfer switch is 2-pole

Christmas Shipping Cut Offs

Enter your zip code for estimated shipping dates

Order by the dates below to get delivery by Christmas
Standard Delivery *Enter zip code for order by date
Express Delivery
Priority Delivery
Premium Delivery

Orders must be placed by 5PM EST.

Certain items require 2-3 business days to ship and is clearly indicated on the product page. These items cannot be expedited.

Delivery times on Economy and Freight orders vary, exact delivery date cannot be determined.